Eastman 3Kva/48v sine Wave

Brand :

₦470,250.00
Emeka Kingsley

OUTPUT PARAMETERS

WaveformPure Sinewave
Voltage Regulation (From min. to max. battery voltage

& no load to full load) (V)

195 – 220
Frequency Regulation50 Hz±1Hz
Peak Efficiency of Inverter89%
Overload Capacity (IT Load Selection)110% for 60Sec. & 150% for 30Sec. & 200% for 2Sec.
Overload Capacity (Normal Load Selection)120% for 60Sec.(3 Retry) & 150% for 30Sec.(3 Retry) & 200% for 2Sec.(No Retry)
Distortion (vTHD)<3%
Crest factor3:01
Short Circuit ProtectionProvided
No load Shutdown (W)10 – 15

GRID USAGE

LCD DisplayBattery Voltage, Charging Current, Discharging Current, Battery Low/High, Battery Charging Unit (kWh) , Battery Discharging Unit (kWh), Solar Voltage,
Solar Current, Solar Instantaneous Power, Solar Commutative Energy Unit (kWh), Grid Voltage,
Grid Current, Grid Commutative Power (kWh),
Grid Instantaneous Power, Grid Frequency, Output Voltage, Output Current, Cumulative Output Power(kWh), Output Instantaneous Power, Output Frequency
LED IndicationsSystem On, Inverter On, Solar Charging On, Grid Charging On, Battery Low/high, Over Load/Heat, Mains Low/high/freq. out, Fault, MPPT Over Heat.
User.Configurable.Parameters through front end LCD displayBattery Low Shutdown, Battery High Cut, Battery Charging Voltage by Solar, Battery Charging Current by Solar, Battery Charging Voltage by Grid, Battery Charging Current by Grid, IT Mode/Normal Mode, Grid Charging Enable/Disable, Operating Modes (PCU, Smart, Hybrid), No Load Shutdown, Input Source (Grid/Genset Mode)
Change over time from Mains to PCU/PCU to Mains<10ms
Grid I/P Voltage range Default (IT load)255V-175V
Grid I/P Voltage range Default (Normal load)280V-120V
Grid Charging Current Default12A (Settable from 8A-20A)
CoolingFan cooling
Charging Current SharingSolar on priority, in case solar current is less, shortfall will be

taken from grid

Grid Charge Current Enable/DisableProvided
Night Grid PriorityAvailable in Smart Mode

Features

  • Advanced MPPT technology ensures upto 30% more energy extraction from Solar panel as compared to PWM based technology
  • Hybrid/PCU/Smart selection mode for high/medium/low power cut areas
  • Pure sine-wave output
  • Advanced DSP based technology LCD Screen for user convenience. User configurable parameters through front end wide screen LCD display
  • Faster change over time to run IT appliances without interruption
  • Grid bypass switch for running connected load in case of system failure
  • Extra safety protections through MCB/fuse Intelligent mixing of Grid current with solar
    in case of solar energy shortfall during cloudy days
  • Highest efficiency in its class
  • Built-in energy meter for Mains, Battery, Solar and Load
  • Temperature compensated (ATC) charging to enhance performance and life of battery upto 30%
  • USB/Ethernet based data logging with data storage facility
  • Grid charging Enable/Disable. No load shut down Enable/Disable IT Mode Enable/Disable.
  • Eastman 3Kva/48v sine Wave
wws Order On WhatsApp
Eastman 3Kva/48v sine Wave

Description

Eastman 3KVA MPPT Solar Off Grid PCU Price Specification

Eastman’s advanced MPPT technology based  Solar Off-Grid PCU has been manufactured in India using world class technology platform and processes. It is a single integrated system with an inbuilt solar charge controller, inverter and grid charger. This  unique hybrid system provides intelligent mixing of grid current with solar in case of solar energy shortfall during cloudy days for maximum solar utilization. The advanced MPPT technology extracts maximum power from the solar panel array giving highest tracking efficiency of >98%. Eastman’s  Solar MPPT based PCU is best suited for residential homes and small commercial establishments.

Specification

Model No.ESM3K/48
PCU VA3000

MPPT SOLAR CHARGE CONTROLLER

TechnologyDSP Based MPPT Charger
Solar ArraySingle Array
Max Solar Panel Wattage3kWp
Input DC Voltage Range (V)72 – 180
Bulk Voltage58.4V (Settable from 54V-60V)
Adjustable Bulk VoltageUser Settable
Transition from float to bulkBelow float level
ProtectionPv Reverse Protection, Reverse Current Flow, High Temperature, Over Current,

Battery Overcharge Protection

Power Conversion Efficiency of Solar Charge Controller96%
Automatic Temperature compensation (Optional)-3mV/ °C/ cell
High Temperature Cut-OFF PCU/ MPPT102°C ± 5°C
High Temperature MPPT Charger Reconnect85°C ± 5°C

INPUT PARAMETERS

Nominal I/P DC Voltage (V)48
Low Battery Warning (V)43.2±0.4
Low Battery Cut off (V)42±0.4

OUTPUT PARAMETERS

WaveformPure Sinewave
Voltage Regulation (From min. to max. battery voltage

& no load to full load) (V)

195 – 220
Frequency Regulation50 Hz±1Hz
Peak Efficiency of Inverter89%
Overload Capacity (IT Load Selection)110% for 60Sec. & 150% for 30Sec. & 200% for 2Sec.
Overload Capacity (Normal Load Selection)120% for 60Sec.(3 Retry) & 150% for 30Sec.(3 Retry) & 200% for 2Sec.(No Retry)
Distortion (vTHD)<3%
Crest factor3:01
Short Circuit ProtectionProvided
No load Shutdown (W)10 – 15

GRID USAGE

LCD DisplayBattery Voltage, Charging Current, Discharging Current, Battery Low/High, Battery Charging Unit (kWh) , Battery Discharging Unit (kWh), Solar Voltage,
Solar Current, Solar Instantaneous Power, Solar Commutative Energy Unit (kWh), Grid Voltage,
Grid Current, Grid Commutative Power (kWh),
Grid Instantaneous Power, Grid Frequency, Output Voltage, Output Current, Cumulative Output Power(kWh), Output Instantaneous Power, Output Frequency
LED IndicationsSystem On, Inverter On, Solar Charging On, Grid Charging On, Battery Low/high, Over Load/Heat, Mains Low/high/freq. out, Fault, MPPT Over Heat.
User.Configurable.Parameters through front end LCD displayBattery Low Shutdown, Battery High Cut, Battery Charging Voltage by Solar, Battery Charging Current by Solar, Battery Charging Voltage by Grid, Battery Charging Current by Grid, IT Mode/Normal Mode, Grid Charging Enable/Disable, Operating Modes (PCU, Smart, Hybrid), No Load Shutdown, Input Source (Grid/Genset Mode)
Change over time from Mains to PCU/PCU to Mains<10ms
Grid I/P Voltage range Default (IT load)255V-175V
Grid I/P Voltage range Default (Normal load)280V-120V
Grid Charging Current Default12A (Settable from 8A-20A)
CoolingFan cooling
Charging Current SharingSolar on priority, in case solar current is less, shortfall will be

taken from grid

Grid Charge Current Enable/DisableProvided
Night Grid PriorityAvailable in Smart Mode

Features

  • Advanced MPPT technology ensures upto 30% more energy extraction from Solar panel as compared to PWM based technology
  • Hybrid/PCU/Smart selection mode for high/medium/low power cut areas
  • Pure sine-wave output
  • Advanced DSP based technology LCD Screen for user convenience. User configurable parameters through front end wide screen LCD display
  • Faster change over time to run IT appliances without interruption
  • Grid bypass switch for running connected load in case of system failure
  • Extra safety protections through MCB/fuse Intelligent mixing of Grid current with solar
    in case of solar energy shortfall during cloudy days
  • Highest efficiency in its class
  • Built-in energy meter for Mains, Battery, Solar and Load
  • Temperature compensated (ATC) charging to enhance performance and life of battery upto 30%
  • USB/Ethernet based data logging with data storage facility
  • Grid charging Enable/Disable. No load shut down Enable/Disable IT Mode Enable/Disable.
  • Eastman 3Kva/48v sine Wave

Reviews

There are no reviews yet.

Be the first to review “Eastman 3Kva/48v sine Wave”